IKO PolymericIKO PolymericIKO PolymericIKO Polymeric
  • Company
    • Company Background
    • Export Markets
    • Partners
    • Our People
    • Our Careers
    • IKO in the Enviroment
    • IKO in the News
  • Products
    • PVC Membranes
    • IKO Spectraplan Membranes
    • Prefabrication Service
    • Vapour Control Layers
    • Thermal Insulation
    • Ancillaries
  • Systems
    • IKO Flat Roof Systems
    • Cold Roof Solutions
    • Warm Roof Solutions
    • Inverted Roof Systems Offering Enhanced Protection
    • Green Roof Systems – Creating a Garden on a Roof
  • Projects
    • Case Studies
    • Library Photos
  • Resources
    • Technical Datasheets & Brochures
    • Technical Bulletins
    • CPD Seminars
    • Product Videos
      • NEW IKO Armourplan Video
    • Technical Support
    • FAQ’s
  • Contact
  • Blog

Blog

Home 2019 June
PVC standing seams

What does a single ply membrane guarantee cover?

By Dave Coldham MIoR | Blog | Comments are Closed | 26 June, 2019 | 0

A single ply membrane guarantee can vary in its range of cover, from being a product guarantee only, to including flat roof system design, to also including workmanship/quality of installation. A product guarantee is based on the properties and characteristics of the membrane that can be tested in isolation. The addition of system design retainsRead more

Glenthorne School, Surrey, IKO Armourplan SM

Is the flat roof system guarantee affected if non-system products are used as part of the installation?

By Dave Coldham MIoR | Blog | Comments are Closed | 24 June, 2019 | 0

Using components not approved as part of a single ply flat roof system can invalidate the manufacturer guarantee. A warranty or guarantee relies on the manufacturer’s knowledge and confidence that all of the component products have been tested in combination and will achieve certain standards of performance. Any product substitutions should be checked and confirmedRead more

IKO Armourplan With Standing Seam

What is the fire rating of single ply membranes?

By Dave Coldham MIoR | Blog | Comments are Closed | 21 June, 2019 | 0

The fire rating of a single ply membrane is determined through standardised testing methods, which take into account the complete flat roof system from the structural deck upwards. There are different fire ratings for construction products depending on what is being tested; for a flat roof system, the resistance of the roof to external fireRead more

How should I store single ply membrane and flat roofing system materials on site?

By Dave Coldham MIoR | Blog | Comments are Closed | 19 June, 2019 | 1

The components of a single ply flat roof system – including the single ply membrane itself and thermal insulation boards – should generally be protected at all times. Preferably they should be stored indoors before use, and afforded as much protection as possible once on the roof awaiting installation. BS 6229:2018, the code of practiceRead more

cleaning_single_ply_membranes_before_welding

How can a single ply membrane flat roof be repaired?

By Dave Coldham MIoR | Blog | Comments are Closed | 17 June, 2019 | 0

A single ply flat roof waterproofing membrane should be repaired in consultation with the membrane manufacturer, to make sure that the correct type of remedial action is taken for the membrane type. In the event of accidental damage to the membrane, the installing contractor and the membrane manufacturer should be notified immediately to agree aRead more

Single Ply Install

Is installer training available for single ply membranes?

By Dave Coldham MIoR | Blog | Comments are Closed | 11 June, 2019 | 0

Is installer training available for single ply membranes? Manufacturers of single ply flat roof membranes offer installer training as part of developing a network of approved or registered contractors. The different materials used to manufacture polymeric single ply membranes depend on different installation techniques, so for system suppliers to guarantee finished roofs it is necessaryRead more

Archive

Subscribe for our blog

CONTACT

Coney Green Road
Clay Cross
Chesterfield
UK
S45 9HZ
Tel: (+44) 01257 488 000
Email: polymeric.sales.uk@iko.com

EXTRA

  • Technical support
  • FAQ’s
  • CPD Seminars
  • Product videos
  • Sitemap
  • Modern Slavery Statement

Copyright © IKO Polymeric | Cookie policy | Privacy policy | Webdesign and SEO by IC Solutions
  • Company
    • Company Background
    • Export Markets
    • Partners
    • Our People
    • Our Careers
    • IKO in the Enviroment
    • IKO in the News
  • Products
    • PVC Membranes
    • IKO Spectraplan Membranes
    • Prefabrication Service
    • Vapour Control Layers
    • Thermal Insulation
    • Ancillaries
  • Systems
    • IKO Flat Roof Systems
    • Cold Roof Solutions
    • Warm Roof Solutions
    • Inverted Roof Systems Offering Enhanced Protection
    • Green Roof Systems – Creating a Garden on a Roof
  • Projects
    • Case Studies
    • Library Photos
  • Resources
    • Technical Datasheets & Brochures
    • Technical Bulletins
    • CPD Seminars
    • Product Videos
      • NEW IKO Armourplan Video
    • Technical Support
    • FAQ’s
  • Contact
  • Blog
IKO Polymeric