IKO PolymericIKO PolymericIKO PolymericIKO Polymeric
  • Company
    • Company Background
    • Export Markets
    • Partners
    • Our People
    • Our Careers
    • IKO in the Enviroment
    • IKO in the News
  • Products
    • PVC Membranes
    • IKO Spectraplan Membranes
    • Prefabrication Service
    • Vapour Control Layers
    • Thermal Insulation
    • Ancillaries
  • Systems
    • IKO Flat Roof Systems
    • Cold Roof Solutions
    • Warm Roof Solutions
    • Inverted Roof Systems Offering Enhanced Protection
    • Green Roof Systems – Creating a Garden on a Roof
  • Projects
    • Case Studies
    • Library Photos
  • Resources
    • Technical Datasheets & Brochures
    • Technical Bulletins
    • CPD Seminars
    • Product Videos
      • NEW IKO Armourplan Video
    • Technical Support
    • FAQ’s
  • Contact
  • Blog

Blog

Home 2018 July
pullout_test

Issue 8: Preparation of In-situ Concrete Decks

By Frank Williamson F.I.o.R | Technical Bulletins | Comments are Closed | 31 July, 2018 | 0

Concrete Specification In-situ Concrete for roof decks shall be specified and produced in accordance with BS EN 206:2013 and installed in accordance with BS13670:2009 and the National Structural Concrete Specification. Normal Weight and Lightweight concretes are suitable substrates for most IKO Waterproofing system applications. As defined in BS EN 206:2013, Normal Weight and Lightweight concreteRead more

rippling_TPE_single_ply_membranes

Issue 7: Rippling In Spectraplan TPE Membranes

By Frank Williamson F.I.o.R | Technical Bulletins | Comments are Closed | 31 July, 2018 | 0

Spectraplan TPE membranes can exhibit surface rippling, particularly with changes in temperature, the effect is also noticeable when the daylight changes from dispersed or diffused light of a cloudy day to direct sunlight. This is an inherent feature of the membrane as a result of in-built extensibility during the manufacturing process. The effect will normallyRead more

Standing-seam-profiles

Issue 6: Roof Maintenance Guidelines

By Frank Williamson F.I.o.R | Technical Bulletins | Comments are Closed | 31 July, 2018 | 0

All Polymeric Membranes 1.0  General Roof maintenance, as with any part of the building, is essential in order to comply with the waterproofing system guarantee and to ensure maximum performance and life expectancy. 2.0  Access Access to the roof must only be allowed under supervision of the Building Manager or the person responsible for buildingRead more

pu_adhesive_single_ply_membrane

Issue 5: Guidance for Working with IKO Polymeric Systems in Cold Weather

By Buket Aydinlik | Technical Bulletins | Comments are Closed | 30 July, 2018 | 0

Use of Adhesives Generally both PU Adhesives and contact adhesives should not be used if the temperature is below 5° C, they should also be stored at 15+°C. Storing the adhesives on the roof overnight during low temperatures is considered poor practice and should be avoided. If this is unavoidable then provision should be madeRead more

gutters_on_flat_roofs

Issue 4: Ponding Water on Flat Roofs

By Buket Aydinlik | Technical Bulletins | Comments are Closed | 30 July, 2018 | 0

Flat roof areas should always be designed in accordance with Codes of Practice to freely drain water either directly to rainwater outlets or to a gutter section, either off the roof elevation or to an internal box gutter section. Ideally internal box gutters should also be constructed with an adequate fall. Should a roof areaRead more

cleaning_single_ply_membranes_before_welding

Issue 3: Methodology for Repairs to Armourplan

By Frank Williamson F.I.o.R | Technical Bulletins | Comments are Closed | 30 July, 2018 | 0

Areas to be worked on should be swept with a soft brush to remove any debris or sharp fines that may be laying on the surface. As well as the area to be repaired the surrounding area should also be swept to reduce the chance of bringing debris back into the work area. The membraneRead more

IKO_strike_lightening_conductor_clip

Issue 2 – PVC coated lightning conductor tapes

By Buket Aydinlik | Technical Bulletins | Comments are Closed | 30 July, 2018 | 0

IKO Polymeric do not recommend the use of PVC coated lightning conductor tapes on Armourplan PVC roofing systems as the PVC coating can cause plasticiser migration from the waterproofing membrane. Plain tapes should be used and secured into position with IKO Strike lightning conductor clips. IKO Strike Lightening Conductor Clip Click here to download thisRead more

armourplan_walkway_membrane

Issue 1: Guidance for Walkway Membrane Usage

By Frank Williamson F.I.o.R | Technical Bulletins | Comments are Closed | 30 July, 2018 | 0

IKO Armourplan PVC membrane is robust enough to withstand light foot traffic for normal roof inspections, which should be carried out at least twice a year. Care should be taken when walking over any areas that may suffer from some water retention as there could be a build-up of silt which is likely o presentRead more

IKO_Polymeric_receiving_best_detailing_spra_award_2018

A Night Full of Achievement

By Buket Aydinlik | News | Comments are Closed | 3 July, 2018 | 0

IKO Polymeric enjoyed a very successful night at this year’s SPRA Awards by winning 5 awards with their projects demonstrating the best use of Single Ply. Working with DVC Roofing, the company was the winner of Best Detailing Award for their Goosecroft Lane project, a residential building in based Northallerton. This complex, multi-slope pitched roofRead more

Archive

Subscribe for our blog

CONTACT

Coney Green Road
Clay Cross
Chesterfield
UK
S45 9HZ
Tel: (+44) 01257 488 000
Email: polymeric.sales.uk@iko.com

EXTRA

  • Technical support
  • FAQ’s
  • CPD Seminars
  • Product videos
  • Sitemap
  • Modern Slavery Statement

Copyright © IKO Polymeric | Cookie policy | Privacy policy | Webdesign and SEO by IC Solutions
  • Company
    • Company Background
    • Export Markets
    • Partners
    • Our People
    • Our Careers
    • IKO in the Enviroment
    • IKO in the News
  • Products
    • PVC Membranes
    • IKO Spectraplan Membranes
    • Prefabrication Service
    • Vapour Control Layers
    • Thermal Insulation
    • Ancillaries
  • Systems
    • IKO Flat Roof Systems
    • Cold Roof Solutions
    • Warm Roof Solutions
    • Inverted Roof Systems Offering Enhanced Protection
    • Green Roof Systems – Creating a Garden on a Roof
  • Projects
    • Case Studies
    • Library Photos
  • Resources
    • Technical Datasheets & Brochures
    • Technical Bulletins
    • CPD Seminars
    • Product Videos
      • NEW IKO Armourplan Video
    • Technical Support
    • FAQ’s
  • Contact
  • Blog
IKO Polymeric